Rigid Wall Sleeve technical overview.
Rigid Wall Sleeve from JINYI is presented in the DN100 · rigid wall sleeve configuration. Use the dimension schedule, connection details and inspection requirements below when comparing this product with your pipework or equipment drawing.
On this page
What is a rigid wall sleeve?
A rigid wall sleeve creates a defined pipe passage through a wall and can incorporate a puddle flange in the specified concrete penetration detail. The sleeve bore and length must suit the carrier pipe, wall thickness and chosen sealing arrangement.

Key dimensions and installation fit
The wall sleeve forms a controlled pipe penetration through a wall or slab. Check the actual carrier-pipe diameter, sleeve diameter, wall thickness and installation depth. A puddle flange addresses the wall interface; a flexible gland or seal addresses the gap between the sleeve and carrier pipe. Review pipe supports and hangers when defining how the carrier pipe is supported on either side of the wall.
How to specify the rigid wall sleeve
Coordinate sleeve material, coating and sealing components with the wall construction and pipe service. Nominal DN alone does not define the annular gap. If movement accommodation is required, specify its direction and permitted displacement rather than assuming that every flexible waterproof sleeve has the same movement capability.
Technical data for the rigid wall sleeve
| Nominal size | DN100 |
|---|---|
| Carrier-pipe dimension D1 | 108 mm |
| Dimension D2 | 130 mm |
| Sleeve outside diameter D3 | 159 mm |
| Puddle flange diameter D4 | 270 mm |
| Wall thickness δ | 4.5 mm |
| Plate dimension b | 10 mm |
| Dimension k | 5 mm |
Sizes and dimensional requirements
The dimensional schedule identifies the illustrated configuration. Compare each value with the mating pipe, equipment or support drawing. A nominal designation does not replace the actual connection diameter, installation envelope or mounting detail. The choices above let you include a different configuration with your quotation request.
Dimensions and tolerance schedule
| Machined length >30–120 mm | ±0.3 mm |
|---|---|
| Machined length >120–400 mm | ±0.5 mm |

Inspection, standards and documentation
Inspect the carrier-pipe surface, sleeve position, flange or gland dimensions and accessible fasteners. Coordinate the assembly with the concrete detail, wall thickness and waterproofing system. Include the required sealing test, installation orientation and finish in the enquiry.
State the required product standard and edition, material records and inspection acceptance criteria before ordering. Where pressure, temperature, movement or load are relevant, provide the operating and test conditions together. Document requirements should identify the actual component and drawing revision; a general certificate does not replace a dimensional or material record for the ordered item. Use the pipe support and casing manufacturing guidance to confirm fabrication and inspection requirements.
Where the rigid wall sleeve is used
- Wall pipe penetrations. Coordinate the sleeve position with wall thickness, carrier-pipe diameter and waterproofing.
- Floor penetrations. Review the embedded assembly and accessible sealing components.
- Waterproofing interfaces. Specify the sealing duty and any required pipe movement accommodation.
How to order a rigid wall sleeve
Select the required options and send the quantity, destination, material and controlled drawing to JINYI. Include changed dimensions, mating details, finish, marking and packing requirements. The quotation defines the final configuration, inspection scope and delivery terms so the component can be checked against the intended installation.
Quantity prices and order preparation
| 1,000–1,999 pcs | US$10.00 per piece |
|---|---|
| 2,000–4,999 pcs | US$9.50 per piece |
| 5,000 pcs and above | US$9.00 per piece |
Freight and taxes are quoted separately. A different material, size or drawing can change the price and delivery requirements. Confirm the agreed specification before manufacture, and keep the drawing revision, selected options and ordered quantity together in the enquiry.
Other JINYI products worth comparing
Compare flexible waterproof sleeve, or review the waterproof casings and sleeves catalog for other connection and configuration choices.
Request a custom rigid wall sleeve quotation from JINYI with the drawing and quantity required for your project.
Rigid Wall Sleeve selection and quotation checklist
The rigid wall penetration requires the sleeve and water-stop arrangement to match the construction detail. Identify the carrier pipe, wall thickness and seal interface before comparing flexible alternatives. Use the photographed product form to identify the arrangement, then use the controlled drawing to define what will be supplied. Similar-looking components can have different end details, load paths or maintenance requirements.
Rigid Wall Sleeve dimensions and tolerances
The first comparison for this rigid wall sleeve is wall thickness and carrier-pipe clearance. Mark the dimensions that control mating, alignment and installation space on the enquiry drawing. Give units for every value and identify the datum from which it is measured. If a dimension is critical, specify its individual tolerance and measurement method rather than relying on a general tolerance note.
The current schedule identifies nominal size: DN100; carrier-pipe dimension d1: 108 mm; dimension d2: 130 mm. Read these entries together with the configuration and tolerance tables above. Reference or example values describe the displayed arrangement; the approved JINYI quotation and drawing define the ordered component. A different interface, material or service condition needs a fresh comparison.
Prepare the material and interface information
For a rigid wall sleeve enquiry, identify the required material designation and supplied condition. Describe the mating components, attachment method and environment. Include the operating temperature and any relevant pressure, movement or structural load. These inputs should describe the actual installation, including changes between normal operation, start-up and maintenance where applicable.
Specify coatings, surface finish and marking separately from the base material. If traceability is needed, identify the record required and how it must correspond to the delivered component. Agree whether inspection covers dimensions, material documentation, welds or functional testing; these are different checks with different acceptance criteria.
Custom rigid wall sleeve quotation
Attach the latest drawing revision, required quantity and delivery destination when contacting JINYI. Highlight departures from the illustrated arrangement, including changed dimensions, connections, finish and packing. For repeat orders, reference the approved configuration and list changes explicitly so an earlier drawing is not assumed to remain current.
The three price tiers above organise the displayed quantity bands. Compare quotes using the same drawing, material, inspection scope and unit of supply. A piece, a segment and a complete assembly are different units where applicable. Confirm freight, taxes, documentation and delivery terms with the final quotation instead of inferring them from the displayed unit price.
Compare related component arrangements
Evaluate this wall sleeve by its actual wall thickness and carrier-pipe clearance and the required rigid sleeve arrangement. The photographs below show separate JINYI products for comparison. They are linked to their own technical pages and are not additional gallery views of this rigid wall sleeve.
| Photo | Related product | Selection detail |
|---|---|---|
![]() | Flexible Waterproof Sleeve | Gland dimensions and sealing clearance. Compare this separate product when the drawing requires its particular arrangement. |
![]() | Pipe Repair Coupling | Diameter range and seal selection. Compare this separate product when the drawing requires its particular arrangement. |
![]() | Plate Flange | Bore clearance and bolt drilling. Compare this separate product when the drawing requires its particular arrangement. |
Questions to resolve before ordering
Which dimensions need checking first?
Start with wall thickness and carrier-pipe clearance and the mating or mounting detail. Check nominal designations against measured dimensions, then review the installation envelope. Photographs help identify the form; the drawing provides the dimensional basis for acceptance.
What should the quotation include?
A rigid wall sleeve quotation should identify the configuration, drawing revision, material, quantity, price basis and agreed inspection records. Keep these details together with the approved order so receiving inspection can compare the delivered product with the specified component.
Independent terminology reference
Hauff wall sleeve interface examples provides an independent reference for component terminology. Use the specified standard and edition where required by the project. This link does not establish JINYI certification, product approval or interchangeability with another manufacturer.
- DN100
- Nominal size
- 108 mm
- Carrier-pipe dimension D1
- ±0.3 mm
- Tolerance
- 3
- Quantity tiers
- Two sealing interfaces — Water can pass at the wall interface or the carrier-pipe interface.
- Actual dimensions — Nominal pipe size alone does not define the sealing gap.
- Carrier seal — The sleeve body does not by itself define the sealing system around the carrier pipe.
At a glance
- Product
- Rigid Wall Sleeve
- Configuration
- DN100 · rigid wall sleeve
- Nominal size
- DN100
- Carrier-pipe dimension D1
- 108 mm
- Dimension D2
- 130 mm
Dimensions and technical specification
| Parameter | Specification |
|---|---|
| Nominal size | DN100 |
| Carrier-pipe dimension D1 | 108 mm |
| Dimension D2 | 130 mm |
| Sleeve outside diameter D3 | 159 mm |
| Puddle flange diameter D4 | 270 mm |
| Wall thickness δ | 4.5 mm |
| Plate dimension b | 10 mm |
| Dimension k | 5 mm |
| Approximate weight | 6.36 kg |