Rigid Wall SleeveWaterproof Sleeves

A rigid wall sleeve creates a defined pipe passage through a wall and can incorporate a puddle flange in the specified concrete penetration detail. Specify dimensions, material and service conditions for a Jinyi quotation.

Wall penetration assembly Drawing review Project enquiry
Price per piece · USD Freight and taxes quoted separately
US$10 1,000–1,999 pcs
US$9.50 2,000–4,999 pcs
Best value US$9 5,000 pcs and above
Nominal size DN100
Material Carbon steel
Wall depth 200 mm
Finish Primer coated
Penetration arrangement Wall penetration
Inspection package Dimensional inspection

Select the requirements for your quotation. The technical tables describe the illustrated configuration.

pcs
Request a quote Talk to an engineer

Indicative total at this quantity US$10,000 Final price confirmed with your quotation.

Customization ability

  • Drawing and dimensional review
  • Material and finish requirements
  • Marking and document requirements
  • Packing and shipment requirements

Key product specifications

Nominal size
DN100
Carrier-pipe dimension D1
108 mm
Dimension D2
130 mm
Sleeve outside diameter D3
159 mm
Puddle flange diameter D4
270 mm
Wall thickness δ
4.5 mm
Plate dimension b
10 mm
Dimension k
5 mm

Supplier

Cangzhou Jinyi Pipe Fittings Manufacturing Co., Ltd. Yanshan · Cangzhou · Hebei · China
JINYI
Product supplier
Hebei
Location
Drawing
Enquiry basis
RFQ
Pricing basis
Pipe fittings Project specifications Custom enquiries

Rigid Wall Sleeve — description and technical data

Request product datasheet
Product overview

Rigid Wall Sleeve technical overview.

Rigid Wall Sleeve from JINYI is presented in the DN100 · rigid wall sleeve configuration. Use the dimension schedule, connection details and inspection requirements below when comparing this product with your pipework or equipment drawing.

What is a rigid wall sleeve?

A rigid wall sleeve creates a defined pipe passage through a wall and can incorporate a puddle flange in the specified concrete penetration detail. The sleeve bore and length must suit the carrier pipe, wall thickness and chosen sealing arrangement.

Rigid wall sleeves with central puddle flanges and open pipe passages
Rigid Wall Sleeve — product configuration and connection layout.

Key dimensions and installation fit

The wall sleeve forms a controlled pipe penetration through a wall or slab. Check the actual carrier-pipe diameter, sleeve diameter, wall thickness and installation depth. A puddle flange addresses the wall interface; a flexible gland or seal addresses the gap between the sleeve and carrier pipe. Review pipe supports and hangers when defining how the carrier pipe is supported on either side of the wall.

How to specify the rigid wall sleeve

Coordinate sleeve material, coating and sealing components with the wall construction and pipe service. Nominal DN alone does not define the annular gap. If movement accommodation is required, specify its direction and permitted displacement rather than assuming that every flexible waterproof sleeve has the same movement capability.

Technical data for the rigid wall sleeve

Rigid Wall Sleeve — illustrated configuration
Nominal sizeDN100
Carrier-pipe dimension D1108 mm
Dimension D2130 mm
Sleeve outside diameter D3159 mm
Puddle flange diameter D4270 mm
Wall thickness δ4.5 mm
Plate dimension b10 mm
Dimension k5 mm

Sizes and dimensional requirements

The dimensional schedule identifies the illustrated configuration. Compare each value with the mating pipe, equipment or support drawing. A nominal designation does not replace the actual connection diameter, installation envelope or mounting detail. The choices above let you include a different configuration with your quotation request.

Dimensions and tolerance schedule

Rigid Wall Sleeve — dimensional tolerances
Machined length >30–120 mm±0.3 mm
Machined length >120–400 mm±0.5 mm
Green rigid wall sleeves showing their central water-stop flanges
Rigid Wall Sleeve — additional view of the same product.

Inspection, standards and documentation

Inspect the carrier-pipe surface, sleeve position, flange or gland dimensions and accessible fasteners. Coordinate the assembly with the concrete detail, wall thickness and waterproofing system. Include the required sealing test, installation orientation and finish in the enquiry.

State the required product standard and edition, material records and inspection acceptance criteria before ordering. Where pressure, temperature, movement or load are relevant, provide the operating and test conditions together. Document requirements should identify the actual component and drawing revision; a general certificate does not replace a dimensional or material record for the ordered item. Use the pipe support and casing manufacturing guidance to confirm fabrication and inspection requirements.

Where the rigid wall sleeve is used

  • Wall pipe penetrations. Coordinate the sleeve position with wall thickness, carrier-pipe diameter and waterproofing.
  • Floor penetrations. Review the embedded assembly and accessible sealing components.
  • Waterproofing interfaces. Specify the sealing duty and any required pipe movement accommodation.

How to order a rigid wall sleeve

Select the required options and send the quantity, destination, material and controlled drawing to JINYI. Include changed dimensions, mating details, finish, marking and packing requirements. The quotation defines the final configuration, inspection scope and delivery terms so the component can be checked against the intended installation.

Quantity prices and order preparation

Rigid Wall Sleeve — three quantity price tiers
1,000–1,999 pcsUS$10.00 per piece
2,000–4,999 pcsUS$9.50 per piece
5,000 pcs and aboveUS$9.00 per piece

Freight and taxes are quoted separately. A different material, size or drawing can change the price and delivery requirements. Confirm the agreed specification before manufacture, and keep the drawing revision, selected options and ordered quantity together in the enquiry.

Other JINYI products worth comparing

Compare flexible waterproof sleeve, or review the waterproof casings and sleeves catalog for other connection and configuration choices.

Request a custom rigid wall sleeve quotation from JINYI with the drawing and quantity required for your project.

Rigid Wall Sleeve selection and quotation checklist

The rigid wall penetration requires the sleeve and water-stop arrangement to match the construction detail. Identify the carrier pipe, wall thickness and seal interface before comparing flexible alternatives. Use the photographed product form to identify the arrangement, then use the controlled drawing to define what will be supplied. Similar-looking components can have different end details, load paths or maintenance requirements.

Rigid Wall Sleeve dimensions and tolerances

The first comparison for this rigid wall sleeve is wall thickness and carrier-pipe clearance. Mark the dimensions that control mating, alignment and installation space on the enquiry drawing. Give units for every value and identify the datum from which it is measured. If a dimension is critical, specify its individual tolerance and measurement method rather than relying on a general tolerance note.

The current schedule identifies nominal size: DN100; carrier-pipe dimension d1: 108 mm; dimension d2: 130 mm. Read these entries together with the configuration and tolerance tables above. Reference or example values describe the displayed arrangement; the approved JINYI quotation and drawing define the ordered component. A different interface, material or service condition needs a fresh comparison.

Prepare the material and interface information

For a rigid wall sleeve enquiry, identify the required material designation and supplied condition. Describe the mating components, attachment method and environment. Include the operating temperature and any relevant pressure, movement or structural load. These inputs should describe the actual installation, including changes between normal operation, start-up and maintenance where applicable.

Specify coatings, surface finish and marking separately from the base material. If traceability is needed, identify the record required and how it must correspond to the delivered component. Agree whether inspection covers dimensions, material documentation, welds or functional testing; these are different checks with different acceptance criteria.

Custom rigid wall sleeve quotation

Attach the latest drawing revision, required quantity and delivery destination when contacting JINYI. Highlight departures from the illustrated arrangement, including changed dimensions, connections, finish and packing. For repeat orders, reference the approved configuration and list changes explicitly so an earlier drawing is not assumed to remain current.

The three price tiers above organise the displayed quantity bands. Compare quotes using the same drawing, material, inspection scope and unit of supply. A piece, a segment and a complete assembly are different units where applicable. Confirm freight, taxes, documentation and delivery terms with the final quotation instead of inferring them from the displayed unit price.

Evaluate this wall sleeve by its actual wall thickness and carrier-pipe clearance and the required rigid sleeve arrangement. The photographs below show separate JINYI products for comparison. They are linked to their own technical pages and are not additional gallery views of this rigid wall sleeve.

Related JINYI products — separate configurations to compare
PhotoRelated productSelection detail
Flexible waterproof sleeve with a bolted gland ring around the pipe openingFlexible Waterproof SleeveGland dimensions and sealing clearance. Compare this separate product when the drawing requires its particular arrangement.
Pipe repair coupling showing its metal shell, black liner and side boltsPipe Repair CouplingDiameter range and seal selection. Compare this separate product when the drawing requires its particular arrangement.
Plate flange standing upright with an open bore and a drilled bolt circlePlate FlangeBore clearance and bolt drilling. Compare this separate product when the drawing requires its particular arrangement.

Questions to resolve before ordering

Which dimensions need checking first?

Start with wall thickness and carrier-pipe clearance and the mating or mounting detail. Check nominal designations against measured dimensions, then review the installation envelope. Photographs help identify the form; the drawing provides the dimensional basis for acceptance.

What should the quotation include?

A rigid wall sleeve quotation should identify the configuration, drawing revision, material, quantity, price basis and agreed inspection records. Keep these details together with the approved order so receiving inspection can compare the delivered product with the specified component.

Independent terminology reference

Hauff wall sleeve interface examples provides an independent reference for component terminology. Use the specified standard and edition where required by the project. This link does not establish JINYI certification, product approval or interchangeability with another manufacturer.

DN100
Nominal size
108 mm
Carrier-pipe dimension D1
±0.3 mm
Tolerance
3
Quantity tiers
  • Two sealing interfaces — Water can pass at the wall interface or the carrier-pipe interface.
  • Actual dimensions — Nominal pipe size alone does not define the sealing gap.
  • Carrier seal — The sleeve body does not by itself define the sealing system around the carrier pipe.

At a glance

Product
Rigid Wall Sleeve
Configuration
DN100 · rigid wall sleeve
Nominal size
DN100
Carrier-pipe dimension D1
108 mm
Dimension D2
130 mm
Specification-led Drawing-based enquiry JINYI

Dimensions and technical specification

ParameterSpecification
Nominal sizeDN100
Carrier-pipe dimension D1108 mm
Dimension D2130 mm
Sleeve outside diameter D3159 mm
Puddle flange diameter D4270 mm
Wall thickness δ4.5 mm
Plate dimension b10 mm
Dimension k5 mm
Approximate weight6.36 kg
Rigid wall sleeves with central puddle flanges and open pipe passages
Fig. 01 · Rigid Wall Sleeve: product photograph. Use the approved drawing for dimensions.
DIMENSIONS & SPECIFICATIONS

Rigid Wall Sleeve dimensions

Configuration: DN100 · rigid wall sleeve. Dimensions are shown with their units; nominal size and measured outside diameter are listed separately.

DIMENSION SCHEDULE

ParameterValueConfiguration
Nominal sizeDN100DN100 · rigid wall sleeve
Carrier-pipe dimension D1108 mmDN100 · rigid wall sleeve
Dimension D2130 mmDN100 · rigid wall sleeve
Sleeve outside diameter D3159 mmDN100 · rigid wall sleeve
Puddle flange diameter D4270 mmDN100 · rigid wall sleeve
Wall thickness δ4.5 mmDN100 · rigid wall sleeve
Plate dimension b10 mmDN100 · rigid wall sleeve
Dimension k5 mmDN100 · rigid wall sleeve
Approximate weight6.36 kgDN100 · rigid wall sleeve
Nominal size
DN100
Carrier-pipe dimension D1
108 mm
Dimension D2
130 mm
Sleeve outside diameter D3
159 mm
Product highlights

Engineering points that matter.

  • Two sealing interfacesWater can pass at the wall interface or the carrier-pipe interface.
  • Actual dimensionsNominal pipe size alone does not define the sealing gap.
  • Carrier sealThe sleeve body does not by itself define the sealing system around the carrier pipe.
Fit
Mating geometry
Grade
Service selection
Scope
Clear quotation

Confirm the selected configuration with JINYI before ordering.

Request a quote

Quality assurance Customization & ordering JINYI

From the drawing to the delivery requirements, agree the details that matter to your project.

Your specification starts the conversation.

Ready to place your order?

Send your rigid wall sleeve drawing, specification and quantity for a quotation.

Request a quote

Frequently asked questions

What rigid wall sleeve dimensions are shown?

The DN100 · rigid wall sleeve schedule includes nominal size: DN100, carrier-pipe dimension d1: 108 mm, dimension d2: 130 mm, sleeve outside diameter d3: 159 mm. Review the complete dimension table alongside the mating component or installation drawing.

Which tolerances should be checked for this rigid wall sleeve?

The dimension schedule lists machined length >30–120 mm: ±0.3 mm; machined length >120–400 mm: ±0.5 mm. Identify the controlled features and inspection method on the order drawing; general machining limits apply to the specified machined features.

How do I request a custom rigid wall sleeve price?

Send JINYI the drawing revision, required dimensions, material, quantity, inspection scope and delivery destination. The page shows three quantity price bands; a change of configuration or material needs an updated quotation.

Does the puddle flange seal around the carrier pipe?

It forms part of the sleeve-to-wall water barrier. The annular space around the carrier pipe requires its own specified sealing arrangement.

Which length should be ordered?

Specify the wall thickness and the required projection or finish at each face. The overall sleeve length follows that detail.

Request a quote

Rigid Wall Sleeve

Contact Us