Clear Opening · Seal · Access
Tank Manhole Covers
Tank manhole covers specified for clear access, sealing duty, opening clearance and the vessel’s pressure and vacuum conditions.
Specification basis
Confirm the applicable drawing and requirements
Inspection scope
Defined against the approved order
Category Tank Manhole Covers Clear Opening · Seal · Access Do not use lid OD
Clear ID
Specification input
Pressure and vacuum
P / V
Specification input
About this range
Design the access around the vessel
Tank manhole covers provide a removable closure for inspection, cleaning and maintenance access. JINYI lists round bolted, oval bolted, swing-bolt and davit manways, with tank heads and other closure components in the same category. Stainless steel manways must be selected for the vessel geometry, medium, temperature and closure duty. A cover suitable for an atmospheric tank is not automatically suitable for pressure or vacuum. The clear opening, rather than the cover’s outside diameter, determines the available access.
- State whether the manway is for hand access, inspection or personnel access. Record the clear opening dimensions and any internal obstruction below the neck. Compare the round bolted manway and oval bolted manway when checking the opening geometry.
- Specify positive design pressure and vacuum separately, including cleaning and draining conditions. Do not infer a pressure rating from cover thickness or bolt count.
- For stainless steel tank manhole covers for process vessels, define exact material grades for the neck, lid, fasteners and all wetted surfaces.
- Match the gasket to product fluid, concentration, cleaning chemicals and temperature. Define the gasket section and replacement reference on the assembly drawing.
- Check opening direction, hinge or davit sweep, lid mass, lifting arrangement and clearance to nearby platforms, insulation and piping.
- Tank heads are vessel shell components, while a complete manway includes a neck, sealing face, closure and fastening arrangement. Specify each item by its actual function.
Featured tank manhole covers
Selected tank manhole covers for project enquiries. Compare the connection, installation and specification details, then request a quotation for your required configuration.
See the full catalogue
A round bolted manway provides a circular access opening closed by a bolted cover. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Round Bolted Manway
View details
A oval bolted manway provides an oval access opening with a bolted cover arrangement. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Oval Bolted Manway
View details
A swing bolt manway uses perimeter swing-bolt hardware to secure the specified access cover. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Swing Bolt Manway
View details
A davit manway combines a tank access closure with a specified arm arrangement for handling the cover. Specify dimensions, material and service conditions for a Jinyi…
- Tank Manhole Covers
Davit Manway
View details
2:1 semi-ellipsoidal head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Elliptical Tank Head
View details
Flat circular cover. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Flat Circular Tank Cover
View detailsTank Manhole Covers catalogue
Browse 13 products in this category. Search the range or compare the available enquiry options. Final materials, dimensions and ratings are confirmed against the selected product and your specification.
Showing 1–13 of 13 products

Conical transition head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Conical Tank Head
View details
A davit manway combines a tank access closure with a specified arm arrangement for handling the cover. Specify dimensions, material and service conditions for a Jinyi…
- Tank Manhole Covers
Davit Manway
View details
Dished-only head / dished disc. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Dished Only Tank Head
View details
2:1 semi-ellipsoidal head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Elliptical Tank Head
View details
Flanged-only head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Flanged Only Tank Head
View details
Flat circular cover. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Flat Circular Tank Cover
View details
Hemispherical head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Hemispherical Tank Head
View details
A oval bolted manway provides an oval access opening with a bolted cover arrangement. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Oval Bolted Manway
View details
A round bolted manway provides a circular access opening closed by a bolted cover. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Round Bolted Manway
View details
Shallow spherical dished head. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Shallow Dished Tank Head
View details
A swing bolt manway uses perimeter swing-bolt hardware to secure the specified access cover. Specify dimensions, material and service conditions for a Jinyi quotation.
- Tank Manhole Covers
Swing Bolt Manway
View details
Tank head with drawing-defined central opening. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Tank Head with Central Opening
View details
DIN 28011 torispherical profile. Material, dimensions and commercial terms confirmed with your quotation.
- Tank Manhole Covers
Torispherical Tank Head
View detailsProduct capabilities
Neck geometry, closure load and access
Custom bolted manway covers for storage tanks require coordination with the vessel fabricator. Supply the tank wall thickness, curvature, neck projection and attachment detail, together with corrosion allowance and service conditions. For bolted tank covers, the sealing face, gasket compression and fastener arrangement must form a documented closure design. If hygienic service is required, define the wetted finish, weld treatment and cleanability criteria in the order. A material grade alone does not establish hygienic compliance or a pressure-vessel approval.
- Pressure: Design value and temperature
- Vacuum: Required external-pressure duty
- Closure: Bolted / swing bolt / davit
- Seal: Compound and section
JINYI // WORKSSpecification
Opening · NeckAccess dimension
Clear ID
Do not use lid OD
Duty check
P / V
Pressure and vacuum
Four checks before specifying tank manhole covers
Use these checks to define the tank manhole covers assembly before comparing prices. Record the decision against the drawing revision and obtain confirmation of the proposed model’s limits.
- Define the access task Choose inspection, maintenance or entry access and state the minimum unobstructed opening.
- Review the vessel interface Record shell curvature, thickness, neck height, orientation and the required attachment weld detail.
- Specify closure components Identify lid, gasket, bolts, hinge or davit and any locking or lifting arrangement.
- Agree the acceptance record Set dimensional, material, weld and leak-test requirements against the approved vessel and manway drawings.
Dimensions and service conditions should be agreed before ordering.
Custom bolted manway covers for storage tanks
For tank manhole covers, provide clear opening, tank geometry, neck dimensions, material, pressure and vacuum duty, temperature and fluid. Include gasket requirements, surface finish, opening direction, hinge or davit clearance, quantities and the vessel design specification.
- Round and oval openings Provide both clear dimensions for an oval opening, plus the neck profile and cover envelope.
- Swing-bolt arrangements Define bolt number, thread, engagement, swing clearance and the specified closure procedure.
- Davit-assisted access Confirm supported lid mass, pivot location, sweep radius and structural attachment details.
- Tank heads and blanks Identify formed profile, crown and knuckle geometry where relevant, straight flange and machining allowances.
Send drawings and the item schedule with your enquiry.
Inspection requirements for tank manhole covers
A manway inspection plan should connect the closure drawing to the vessel design requirements. Check opening size, neck geometry, sealing face and the assembled fastening system. Pressure, vacuum and leak-test conditions must be expressly agreed for the selected assembly.
Inspection checklist
Specify in the order- Access geometryClear opening, neck height, orientation and shell-fit dimensions.
- Wetted materialsGrade, surface condition and traceability where specified.
- Sealing interfaceFace flatness, gasket seating and controlled closure alignment.
- Moving componentsHinge or davit travel, fastening engagement and clearances.
- Test documentationAgreed weld examination and leak or pressure-test acceptance.
Order documentation
Scope to confirm- Approved drawingDimensions, revision and acceptance criteria
- Material recordSpecify traceability and document type
- Inspection reportAgree measured items and test scope
- Project approvalsConfirm any required certificates before ordering
JINYI // QCQuality
Inspection · gauging
Standards · documents
Review checkpoints
Document control
Six inspection planning steps
A purchase-order checklist- 1
Drawing review
Confirm the specification, revision and the selected tank manhole covers configuration.
- 2
Access geometry
Clear opening, neck height, orientation and shell-fit dimensions.
- 3
Wetted materials
Grade, surface condition and traceability where specified.
- 4
Sealing interface
Face flatness, gasket seating and controlled closure alignment.
- 5
Moving components
Hinge or davit travel, fastening engagement and clearances.
- 6
Test documentation
Agreed weld examination and leak or pressure-test acceptance.
Applications and specification priorities
Common application contexts for tank manhole covers. Each installation needs a service-specific selection; the entries below describe engineering priorities, not customer projects or approvals.
Technical selection and common questions
Circular tank-cover selection
Read the reference scope
Confirm applicability to your selected designVacuum-duty cover example
Read the reference scope
Confirm applicability to your selected designJINYI technical help
Read the reference scope
Confirm applicability to your selected design
Dimension schedule
Record these fields on a drawing or item schedule. Each quotation for tank manhole covers should identify the proposed configuration and any departure from the specified interface.
Discuss your specification
Service and installation
Include these conditions with the tank manhole covers enquiry. A useful comparison checks technical compliance, inspection scope and installation requirements before comparing unit price.
Discuss your specificationQ&AAnswers for tank manhole covers
Selection questions
Is a tank manhole cover a road manhole cover?
No. This category concerns access closures on tanks and vessels. Traffic-rated drainage covers have different loading, installation and product standards.
Does stainless steel mean pressure-rated?
No. Material choice and pressure design are separate decisions. The complete neck, lid, gasket and fastening system needs a documented rating for the specified temperature and vacuum conditions.
Need help with a specific drawing? Include the service conditions in your enquiry.
Discuss your specificationQ&AAnswers for tank manhole covers
Installation questions
Why specify vacuum on a storage tank?
Draining, cooling or cleaning can create an external-pressure differential. Identify the design conditions and the vessel’s venting arrangement before selecting the cover.
Can a tank head replace a manway?
A formed tank head closes part of the vessel shell. It is not a complete removable access assembly unless a suitable opening, neck, seal and closure system are incorporated into the engineered design.
Need help with a specific drawing? Include the service conditions in your enquiry.
Discuss your specificationRelated products for your assembly
Explore complementary products from other JINYI categories. Check each product’s dimensions and connection requirements against your assembly drawing.
See the full catalogue
- Nominal size
- DN100
- Pressure designation
- PN16
- Outside diameter
- 220 mm
- Bolt circle diameter
- 180 mm
Blind Flange
View details
- Nominal size
- 4 in / DN100
- Run outside diameter
- 114.3 mm
- Branch outside diameter
- 114.3 mm
- Run centre-to-end C
- 105 mm
Equal Pipe Tee
View details
- Nominal size
- DN100
- Pipe outside diameter
- 114.3 mm
- Pressure options
- 1.0 / 1.6 / 2.5 MPa
- Housing arrangement
- 2-piece
Pipe Repair Coupling
View details
- Nominal size
- DN100
- Carrier-pipe diameter D1
- 108 mm
- Sleeve diameter D2
- 146 mm
- Gland bore D3
- 114 mm
Flexible Waterproof Sleeve
View detailsRequest a tank manhole covers quotation
For tank manhole covers, provide clear opening, tank geometry, neck dimensions, material, pressure and vacuum duty, temperature and fluid. Include gasket requirements, surface finish, opening direction, hinge or davit clearance, quantities and the vessel design specification.
Attach the approved drawing, item schedule and service conditions. Identify mandatory documents, inspection hold points and delivery requirements when requesting a quotation.
- Drawing-based review
- Service-specific selection
- Inspection scope agreed
JINYI Fittings