Loads · Travel · Restraint
Pipe Supports & Hangers
Pipe supports and hangers selected for calculated loads, thermal travel, insulation thickness and the supporting structure.
Specification basis
Confirm the applicable drawing and requirements
Inspection scope
Defined against the approved order
Category Pipe Supports & Hangers Loads · Travel · Restraint Define every load case
kN
Specification input
State direction and travel
mm
Specification input
About this range
Support the load. Allow the required movement.
Pipe supports carry the weight of pipework, contained fluid, insulation and attached equipment while controlling movement according to the stress design. JINYI’s category includes pipe shoes, clamps, saddles, riser supports, support frames, spring pipe hangers and constant spring supports. A support selected only by pipe diameter can be unsuitable for the load or operating displacement. Industrial pipe supports should be specified from the support schedule and structural interfaces, with cold and hot positions, load cases and permitted degrees of freedom recorded separately.
- Define sustained operating, empty, hydrotest and occasional load cases in N or kN. Include the contents of the pipe and the applicable insulation system.
- Provide vertical, axial and lateral travel with an explicit positive direction. Distinguish installation position, normal operating position and extreme positions.
- Variable spring hangers for thermal movement change force as the spring moves. Use the selected spring rate and travel to check load variation against the piping design criterion.
- Constant spring supports are considered where the permitted load variation is small relative to the required vertical movement. Confirm usable travel and adjustment range. Compare the horizontal constant spring hanger and compact constant spring support when checking the available mounting space.
- For insulated pipework, specify insulation thickness, support elevation, insert material and vapour-barrier continuity for cold service.
- Separate the support function from the product shape: a shoe may slide, guide or anchor depending on the complete assembly and its structural attachment.
Featured pipe supports & hangers
Selected pipe supports & hangers for project enquiries. Compare the connection, installation and specification details, then request a quotation for your required configuration.
See the full catalogue
An insulated pipe support supports a pipe through an insulating insert and a structural support assembly.. Specify dimensions, material and service conditions for a Jinyi quotation.
- Pipe Supports & Hangers
Insulated Pipe Support
View details
A clamp pipe shoe transfers load from a pipe through a clamp assembly to a supporting base.. Specify dimensions, material and service conditions for a Jinyi…
- Pipe Supports & Hangers
Clamp Pipe Shoe
View details
A spring pipe hanger suspends a specified pipe load while allowing the vertical travel required by the support design.. Specify dimensions, material and service conditions for…
- Pipe Supports & Hangers
Spring Pipe Hanger
View details
A base mounted spring support carries a specified load from below while accommodating the vertical movement required by the piping design.. Specify dimensions, material and service…
- Pipe Supports & Hangers
Base Mounted Spring Support
View details
A pipe saddle support supports the underside of a pipe or cylindrical component through a curved seat.. Specify dimensions, material and service conditions for a Jinyi…
- Pipe Supports & Hangers
Pipe Saddle Support
View details
A split pipe clamp surrounds a specified pipe with separable clamp sections secured by fasteners.. Specify dimensions, material and service conditions for a Jinyi quotation.
- Pipe Supports & Hangers
Split Pipe Clamp
View detailsPipe Supports & Hangers catalogue
Browse 13 products in this category. Search the range or compare the available enquiry options. Final materials, dimensions and ratings are confirmed against the selected product and your specification.
Showing 1–13 of 13 products

A base mounted spring support carries a specified load from below while accommodating the vertical movement required by the piping design.. Specify dimensions, material and service…
- Pipe Supports & Hangers
Base Mounted Spring Support
View details
A clamp pipe shoe transfers load from a pipe through a clamp assembly to a supporting base.. Specify dimensions, material and service conditions for a Jinyi…
- Pipe Supports & Hangers
Clamp Pipe Shoe
View details
Compact constant effort support. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Compact Constant Spring Support
View details
Fabricated support frame · project drawing. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Fabricated Support Frame
View details
Gusseted riser support · engineered reactions. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Gusseted Riser Pipe Support
View details
Horizontal constant effort hanger. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Horizontal Constant Spring Hanger
View details
An insulated pipe support supports a pipe through an insulating insert and a structural support assembly.. Specify dimensions, material and service conditions for a Jinyi quotation.
- Pipe Supports & Hangers
Insulated Pipe Support
View details
A pipe saddle support supports the underside of a pipe or cylindrical component through a curved seat.. Specify dimensions, material and service conditions for a Jinyi…
- Pipe Supports & Hangers
Pipe Saddle Support
View details
Riser clamp · pipe fit and load to project design. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Riser Pipe Clamp
View details
A split pipe clamp surrounds a specified pipe with separable clamp sections secured by fasteners.. Specify dimensions, material and service conditions for a Jinyi quotation.
- Pipe Supports & Hangers
Split Pipe Clamp
View details
A spring pipe hanger suspends a specified pipe load while allowing the vertical travel required by the support design.. Specify dimensions, material and service conditions for…
- Pipe Supports & Hangers
Spring Pipe Hanger
View details
U-bolt · actual pipe OD and thread to specification. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
U Bolt Pipe Support
View details
Weld-on shoe · pipe OD and reactions to drawing. Material, dimensions and commercial terms confirmed with your quotation.
- Pipe Supports & Hangers
Welded Pipe Shoe
View detailsProduct capabilities
Load paths, spring rates and interfaces
Pipe supports and hangers for process piping connect the stress model to the steelwork. The specification should identify where the load enters the clamp or shoe, how it reaches the supporting structure and which movements remain free. For a variable spring, force change is calculated from ΔF = k × Δy using consistent units. As an illustrative calculation, a 20 N/mm spring moving 25 mm changes force by 500 N; this is an example, not a JINYI product rating. The project engineer determines whether that variation is acceptable.
- Axial movement: mm, hot and cold
- Pipe temperature: Design and operating °C
- Insulation: Thickness and insert
- Function: Rest / guide / anchor / spring
JINYI // WORKSSpecification
Design reactions · Vertical movementSupport load
kN
Define every load case
Movement
mm
State direction and travel
Four checks before specifying pipe supports
Use these checks to define the pipe supports assembly before comparing prices. Record the decision against the drawing revision and obtain confirmation of the proposed model’s limits.
- Review the support schedule Match support tag, pipe size, temperature, cold and hot loads, movement vectors and installation elevation.
- Select the support function Choose resting, sliding, guiding, anchoring, suspended or spring-supported behaviour from the approved stress design.
- Check the load path Verify clamp contact, shoe height, rod alignment, base plate, structural connection and permitted side loads.
- Record installation settings Document cold setting, travel indicator position, adjustment range and the procedure for removing transport restraints.
Dimensions and service conditions should be agreed before ordering.
Pipe supports and hangers for process piping
For pipe supports, send the tagged support schedule, pipe OD and wall, operating temperature, insulation thickness, load cases and signed movement vectors. Include available installation height, structural connection drawings, finish requirements and any spring load–travel documentation required.
- Pipe shoes and saddles Provide contact geometry, pipe wall, attachment weld requirements, shoe height and sliding-surface details.
- Suspended hangers Define rod length, thread size, structural attachment, available headroom and allowable angular displacement.
- Spring assemblies Supply cold load, hot load, vertical travel, load-variation criterion and required reserve travel.
- Frames and riser supports Provide vertical reactions, lateral actions, bolt pattern, steel grade, coating and the supporting-structure drawing.
Send drawings and the item schedule with your enquiry.
Inspection requirements for pipe supports
Support inspection should compare the assembly with its approved drawing and support schedule. For springs, request the load–travel record where specified. Dimensional inspection alone does not establish that a support provides the correct operating load or restraint.
Inspection checklist
Specify in the order- Material and sectionCheck steel grade, plate thickness, section size and fastener identification.
- Critical dimensionsVerify shoe height, clamp diameter, rod thread and base-plate hole centres.
- Fabricated jointsAgree weld inspection, acceptance level and coating preparation.
- Spring settingCheck cold load, rated travel, indicators and transport-lock identification.
- Assembly identificationMark the support tag, orientation and installation reference on the dispatch records.
Order documentation
Scope to confirm- Approved drawingDimensions, revision and acceptance criteria
- Material recordSpecify traceability and document type
- Inspection reportAgree measured items and test scope
- Project approvalsConfirm any required certificates before ordering
JINYI // QCQuality
Inspection · gauging
Standards · documents
Review checkpoints
Document control
Six inspection planning steps
A purchase-order checklist- 1
Drawing review
Confirm the specification, revision and the selected pipe supports configuration.
- 2
Material and section
Check steel grade, plate thickness, section size and fastener identification.
- 3
Critical dimensions
Verify shoe height, clamp diameter, rod thread and base-plate hole centres.
- 4
Fabricated joints
Agree weld inspection, acceptance level and coating preparation.
- 5
Spring setting
Check cold load, rated travel, indicators and transport-lock identification.
- 6
Assembly identification
Mark the support tag, orientation and installation reference on the dispatch records.
Applications and specification priorities
Common application contexts for pipe supports. Each installation needs a service-specific selection; the entries below describe engineering priorities, not customer projects or approvals.
Technical selection and common questions
Spring hanger operating principles
Read the reference scope
Confirm applicability to your selected designConstant support principles
Read the reference scope
Confirm applicability to your selected designJINYI technical help
Read the reference scope
Confirm applicability to your selected design
Dimension schedule
Record these fields on a drawing or item schedule. Each quotation for pipe supports should identify the proposed configuration and any departure from the specified interface.
Discuss your specification
Service and installation
Include these conditions with the pipe supports enquiry. A useful comparison checks technical compliance, inspection scope and installation requirements before comparing unit price.
Discuss your specificationSelection questions
When is a spring hanger needed?
Consider a spring hanger where vertical pipe movement must occur while a defined supporting force is maintained. The need and allowable load variation come from the piping stress analysis.
Are variable and constant springs interchangeable?
No. Variable springs change load with travel; constant assemblies are designed to keep support force approximately constant over their rated stroke. Compare the design loads, travel and permitted deviations.
Need help with a specific drawing? Include the service conditions in your enquiry.
Discuss your specificationInstallation questions
Can pipe diameter determine the support spacing?
Diameter is only one input. Pipe material, wall, contents, insulation, temperature, concentrated loads and allowable deflection also affect the spacing and reactions.
What changes for chilled-water supports?
Cold-service details should address condensation, insulation compression and the vapour barrier. Specify an appropriate load-bearing insulation insert and the required thermal separation.
Need help with a specific drawing? Include the service conditions in your enquiry.
Discuss your specificationRelated products for your assembly
Explore complementary products from other JINYI categories. Check each product’s dimensions and connection requirements against your assembly drawing.
See the full catalogue
- Component
- Metal bellows expansion joint
- Nominal size and ends
- Specify DN/NPS, flange standard or weld-end geometry
- Design conditions
- Pressure, temperature and process medium together
- Movement
- Axial, lateral and angular demands and combinations
Metal Bellows Expansion Joint
View details
- Nominal size
- 4 in / DN100
- Pipe outside diameter
- 114.3 mm
- Bend angle
- 90°
- Centreline radius
- 152.4 mm
90 Degree Pipe Elbow
View details
- Nominal size
- 4 in / DN100
- Pressure designation
- Class 150
- Outside diameter
- 228.6 mm
- Flange thickness
- 22.35 mm
Weld Neck Flange
View details
- Nominal size
- 4 in / DN100
- Pipe outside diameter
- 114.3 mm
- Assembled dimension X
- 146 mm
- Assembled dimension Y
- 210 mm
Grooved Pipe Coupling
View detailsRequest a pipe supports quotation
For pipe supports, send the tagged support schedule, pipe OD and wall, operating temperature, insulation thickness, load cases and signed movement vectors. Include available installation height, structural connection drawings, finish requirements and any spring load–travel documentation required.
Attach the approved drawing, item schedule and service conditions. Identify mandatory documents, inspection hold points and delivery requirements when requesting a quotation.
- Drawing-based review
- Service-specific selection
- Inspection scope agreed
JINYI Fittings